Updated: May 26, 2024

Published: April 16, 2021

Measuring AST Levels in Preclinical Safety Studies In Vitro – Closing the Gap to Clinical Data

InSphero's Scientific Ambassador Sue Grepper, Ph.D., highlights how to recapitulate clinically observed increases of Aspartate Transaminase (AST) levels in preclinical in vitro safety studies.

If you have experienced a clinical study where your developed therapeutics resulted in increased levels of aspartate aminotransferase (AST) and alanine transaminase (ALT), you may wonder how to recapitulate these effects in preclinical in vitro safety studies. This has been a major challenge for in vitro models in the past, but I am excited to say that there is now the possibility to measure AST in liver spheroids! This should further improve the predictability of in vitro models, as well as close the gap to clinical data.

Why do we care about AST and ALT?

As you may already know, Aspartate Transaminase AST and ALT levels are typically measured in clinical trials to detect drug-induced liver injury (DILI).  They are both released from compromised hepatocyte cell membranes following a necrotic event and in patients, the measurement and ratio of ALT/AST in the blood is a biomarker for liver damage (as ALT is more primarily found in the liver, whereas AST is more promiscuously expressed throughout the body). Sometimes elevations in these liver toxicity biomarkers pop up in Phase 1 “drug safety trials”, but all too often, they don’t reveal themselves until larger, even more expensive, Phase 2 and Phase 3 efficacy trials, or even post-market.

So we all wonder: why didn’t preclinical models predict these fatal liabilities?  Besides the ethical concerns of using animal tox models, the expression of metabolic enzymes and transporters differ greatly between different species, all of which can impact downstream DILI. As for in vitro human models, immortalized human cell lines or even primary human cells plated in 2D lack the functionality and longevity of 3D cultures necessary to predict hepatotoxicity properly. This has been highlighted in numerous papers such as this one, with endpoints such as ATP, LDH, HMGB1, miR122, etc.

However, when trying to directly translate AST and ALT levels from the bench to the clinic, this has been very difficult for all in vitro models. Most kits’ limit of detection are too high for measuring this transaminase in vitro. Nevertheless, there is an understandable demand for direct translation between the bench and the clinic for this valuable endpoint.

Where is the proof?

InSphero has been up for the challenge. We have spent several years testing different kits for detecting AST and ALT and have finally optimized a powerful system that accurately predicts DILI using AST as the endpoint. AST measurements from toxic compounds are found to be remarkably consistent with that of LDH, just at a much lower scale. Furthermore, these AST measurements are coming exclusively from liver cells in this human model, so there isn’t a need to calculate the ratio of ALT/AST or even measure ALT at all.

Our proof-of-concept studies have included numerous toxic compounds (for example, Troglitazone shown below) with concurrent AST, LDH, and ATP measurements. All three of these endpoints can be multiplexed from the same spheroid microtissue/well.

An image showing Liver spheroids treated with Troglitazone. Complex liver microtissues, containing primary human hepatocytes, endothelial cells, and Kupffer cells, were treated with Troglitazone on days 0, 2, and 5. Secreted LDH and AST were measured from supernatant collected at days 2, 5, and 7. ATP was measured from cell lysate at day 7.
Figure 1. Liver spheroids treated with Troglitazone. Complex liver microtissues, containing primary human hepatocytes, endothelial cells, and Kupffer cells, were treated with Troglitazone on days 0, 2, and 5. Secreted LDH and AST were measured from supernatant collected on days 2, 5, and 7. ATP was measured from cell lysate on day 7.

With these new scientific developments, we can help to get that much closer to predictive clinical translation. Please contact me at sue.grepper@insphero.com if you would like to learn more about liver toxicity testing options.

Vitruvian Mouse, Microtissue, and Man illustration by David Dean.

Read More

FDA Modernization Act 3.0
Blog

The FDA Modernization Act 3.0: Paving the Way for a New Era in Drug Development or a Gentle Nudge?

In a significant step toward making drug development more patient-centric, the FDA Modernization Act 3.0 was introduced as a major piece of forward-looking legislation in February 2024. For stakeholders across the biopharmaceutical industry, including companies like InSphero that specialize in complex in vitro models, this legislation presents both promising opportunities and new challenges. Will it change things?

Read the full blog post »