Gri3D® Hydrogel Microcavity Plates

Ready-to-Use 96-Well Plates for Reproducible 3D Organoid Culture

Gri3D® Hydrogel Microcavity Plate

Gri3D® Hydrogel Microcavity Plates combine precisely defined arrays of PEG hydrogel microcavities with a standard 96-well plate format to provide a controlled environment for 3D cell culture. The unique design enables cells to self-organize into uniform spheroids and organoids, supporting reproducible tissue formation across a broad range of biological models. As a ready-to-use platform, Gri3D® integrates seamlessly into both manual and automated workflows.

Why choose Gri3D® for organoid culture?

  • Reproducible organoid formation: Defined U-shaped microcavities promote uniform tissue formation and help reduce variability between organoids
  • Flexible model development: Support a wide range of 3D models, from simple spheroids to complex, self-organizing organoids
  • Flexible 96-well format: Choose from 31–121 microcavities per well, with microcavity diameters ranging from 400 to 800 µm
  • Simplified handling: A dedicated pipetting port helps retain organoids during manual or automated liquid handling
  • High-content imaging: Optically clear hydrogel and consistent organoid positioning simplify image-based analysis
  • Scalable workflows: ANSI/SLAS-standard plates support automated cell seeding, medium exchange, and compound treatment, making it easier to transition from model development to higher-throughput studies
Gri3D Hydrogel Microplates

Gri3D® Hydrogel Microcavity Plate Product Documents

Gri3D® Hydrogel Microcavity Plates

Gri3D® One Platform – Endless Possibilities

Selection Guide Akura™/Gri3D®

High-throughput Modeling of Inflammatory Bowel Disease Using Human Intestinal Organoids

Frequently Asked Questions

A protocol for the production of organoids in the Gri3D® plate is provided in the product manual. Below are answers to some frequently asked questions to help get you started.

What is a microcavity?

A microcavity is a small, precisely defined U-shaped cavity formed in the PEG hydrogel at the bottom of each Gri3D® well. Cells settle into these cell-repellent microcavities, where they aggregate to form spheroids or organoids. By providing defined locations for 3D tissue formation, the microcavity array supports reproducible cell culture and enables a variety of downstream analyses, including biochemical, lytic, and image-based assays.

Gri3D® uses a standard 96-well plate format, but each well contains an array of multiple hydrogel microcavities. The well serves as the main culture compartment, while each microcavity provides a defined location for an individual spheroid or organoid to form. Depending on the plate configuration, each well contains between 31 and 121 microcavities. 

Upon receipt, store the Gri3D® Plate at 4°C (32°F). The plate has a shelf life of at least six months when stored unopened at the recommended temperature. It is essential to keep the hydrogel hydrated in its storage buffer, as drying out will permanently compromise its functionality and render the plate unusable. When stored unopened at 4°C (32°F), the hydrogel will remain hydrated throughout the specified storage period.

Yes. Gri3D has ANSI/SLAS format and is designed for automated 3D cell culture workflows. Cell seeding, medium exchange and compound treatment can be performed using liquid-handling systems. The dedicated pipetting port enables medium exchange while helping protect the organoids in the microcavity array from aspiration or disturbance. 

We have 2 different Gri3D plates available:  

  • The Gri3D Hydrogel Microcavity Plate – Plastic, which is made of Polystyrene with a 1 mm bottom. This plate is recommended for bio-chemical- and lytic assays. 
  • The Gri3D Hydrogel Microcavity Plate – Imaging, which is made of COP with a 180 µm thin imaging membrane, well suited for bio-chemical- and lytic assays, and high-content imaging applications. 

Both plates are filled with Hydrogel microcavities (poly-ethylene glycol (PEG)).

If you are using the Gri3D plate for the first time, we recommend purchasing our Gri3D Sample Plate to help you identify the most suitable microcavity size for your organoid model. 

The sample plate includes: 

  • Gri3D® sample plate available for standard sizes
  • Contains 1 column filled with hydrogel for each of the standard microcavity sizes (400, 500, 600 and 800 µm) 
  • 4 columns in total 

Price: 100 CHF/USD/Euro plus shipment costs 

Figure 1: Design of Gri3D® sample plate. 

No, our PEG-based hydrogels are pre-formed, attached to the bottom of the Gri3D® plate and require no prior knowledge in hydrogel handling. PEG-based hydrogels are cell repellent by nature allowing precise organoid aggregation from ten to multiple thousands of cells. Their versatile chemistry ensures optimal organoid protocols.  

Here’s how to get started: 

Gri3D® plates are available with microcavity diameters ranging from 400 to 800 µm. Smaller microcavities are generally suited to smaller organoids or models starting from lower cell numbers and provide more microcavities per well. Larger microcavities can accommodate organoids that are expected to grow for longer periods or reach larger sizes. The optimal configuration depends on your cell type, starting cell number, culture duration and desired final organoid size.  

Our Gri3D® plates have been used to grow various models including but not limited to intestinal organoids, liver organoids, colorectal and pancreatic cancer organoids, blood-brain barrier organoids. 

Each Gri3D® well requires 50 µL of a single-cell suspension. The optimal cell seeding density depends on your specific application, the growth rate of the cells, and the desired final organoid size. You can adjust the starting cell number to control organoid size and growth. 

For guidance on selecting the appropriate seeding density, please refer to the protocol provided with the product or explore our resources for established models. 

The recommended cell seeding density ranges are listed below. To calculate the number of cells required to prepare 1 mL of cell seeding suspension, use the following formula: 

Cell seeding density (cells/mL) = # of cells per aggregate × # of microwells × 20 

You may also like

InSphero Incubox™

InSphero Incubox™

Akura™ Tilting Stand

Akura™ 3D SureKit

Akura™ 384 Spheroid Microplate

Your Success is Our Mission - Get in Touch

Fill in form below to contact our 3D in vitro experts

Sign up for our Newsletter

Get the latest news on 3D in vitro research

View resource

Fill in the form below to view this resource